Promise Technology VTRAK M610p Manuel Page 232

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 284
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 231
VTrak M610p Product Manual
220
CLU Reports a Problem
The CLU reports information passively—you must determine which functions to
check based on the sound of the VTrak’s audible alarm (see page 214) and any
amber or red LEDs (see page 215).
Check the event logs first. Then check the reported component.
Viewing Runtime Events
To display Runtime Events:
1. From the Main Menu, highlight Event Viewer and press Enter.
The log of Runtime Events appears. Events are added to the top of the list.
Each item includes:
Sequence number – Begins with 0 at system startup.
Device – Disk Array, Logical Drive, Physical Drive by its ID number.
Severity – (lowest to highest) Information, Warning, Minor, Major,
Critical and Fatal
Timestamp – Date and time the event happened.
Description – A description of the event in plain language.
Press the up and down arrow keys to scroll through the log.
Viewing NVRAM Events
This screen displays a list of and information about 63 most important events
over multiple subsystem startups.
To display NVRAM events:
1. From the Main Menu, highlight Event Viewer and press Enter.
2. Highlight NVRAM Events and press Enter.
The log of NVRAM Events appears. Events are added to the top of the list.
Each item includes:
Sequence number – Begins with 0 at system startup.
Device – Disk Array, Logical Drive, Physical Drive by its ID number.
Severity – (lowest to highest) Information, Warning, Minor, Major,
Critical and Fatal
Timestamp – Date and time the event happened.
Description – A description of the event in plain language.
3. Press the up and down arrow keys to scroll through the log.
Vue de la page 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 283 284