Chapter 6: Management with the CLU
265
4. Highlight following and press the spacebar to toggle through Low, Medium,
and High rates:
Rebuild – Checks the data integrity on disk arrays
Migration – Change RAID level or add physical dries to disk arrays
PDM – Looks for bad blocks on the physical drives of disk arrays
Transition Returns a revertible spare drive to spare status
Synchronization – Checks the data integrity on disk arrays
Initialization – Sets all data bits in the logical drive to zero
Redundancy Check – Checks, reports and can correct data
inconsistencies in logical drives
The rates are defined as follows:
Low – Fewer resources to activity, more to data read/write.
Medium – Balance of resources to activity and data read/write.
High – More resources to activity, fewer to data read/write.
5. Highlight the following PDM trigger settings and press the backspace key to
erase the current value:
Reassigned Block Threshold – 1 to 512 blocks
Error Block Threshold – 1 to 2048 blocks
6. Press Ctrl-A to save your settings.