Chapter 4: Management with WebPAM PROe
163
4. From the dropdown menu the Background Activities tab, choose Start
Migration.
5. Highlight physical drives you want in the disk array from the Available list and
press the >> button to move them to the Selected list.
You can also double-click them to move them.
The available drives are either HDD or SSD, depending on the type of drives
in the array.
6. When you are done, click the Next button.
7. Select a new RAID Level, if desired.
8. To expand the disk array's capacity, check the Expand Capacity box.
9. If you checked the Expand Capacity box, enter a number into the Capacity
field and choose the appropriate unit of measure (MB, GB, TB).
10. Under Capacity Usage, highlight the logical drive whose RAID level you want
to change or whose capacity you want to expand.
11. Click the Update button.
The logical drive changes to reflect your choices.
12. Update other logical drives using the same method.
13. When you are done making the changes, click the Next button.
14. Click the Submit button to begin Migration.
To set Migration priority, see “Making Background Activity Settings” on page 71.
Rebuilding a Disk Array
When you rebuild a disk array, you are actually rebuilding the data on a
replacement physical drive.
Rebuilding Automatically
Normally, a disk array would rebuild itself using a hot disk drive, after going
Critical. However, if the Auto Rebuild function is disabled or no spare drives are
available, you must initiate the procedure.
To enable Auto Rebuild, see “Making Background Activity Settings” on page 71.
To create a spare drive, see “Creating a Spare Drive” on page 176.
For more information, see “Hot Spare Drive(s)” on page 350.
Rebuilding Manually
If a physical drive has failed, identify and replace the drive, then rebuild the disk
array as described below:
1. Click the Subsystem icon in Tree View.