Promise Technology E610s Manuel Page 361

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 434
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 360
Chapter 8: Troubleshooting
343
Overheating
Overheating is a potentially serious condition because the
excessively high temperatures can lead to disk drive failure and
controller malfunction.
Overheating usually results from:
Fan failure
Poor air circulation around the enclosure
WebPAM PROe reports failed fans along with elevated
temperature. On VTrak, there are two kinds of fans:
Power supply
Cooling unit
If a power supply fan fails, you must replace the power supply. If
a cooling unit fan fails, you can remove the cooling unit and
replace only the fan itself.
No tools are required for either procedure. See “Replacing a
Power Supply” on page 259 and “Replacing a Cooling Unit Fan or
Blower” on page 260.
Air circulation around the VTrak enclosure may be a more
complex problem. Use the thermometer icons to help you locate
the specific hot spot. Check for these conditions:
Accumulated dust or objects blocking the fans
Less than a minimum of 5 inches (13 cm) space between the
back of the VTrak and the wall or other object
Ambient temperature above 95°F (35°C) where the VTrak is
operating
To cool down a VTrak:
Correct any problems identified above
Power it down and let it sit for an hour or longer
Vue de la page 360
1 2 ... 356 357 358 359 360 361 362 363 364 365 366 ... 433 434

Commentaires sur ces manuels

Pas de commentaire