Promise Technology E610f Manuel Page 357

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 436
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 356
Chapter 8: Troubleshooting
335
JBOD
JBOD system connected No action is required.
JBOD system either is removed or
malfunctioned
Check Expander firmware and SAS
connections.
Logical Drive
Logical drive initialization has started
No action is required.
Logical drive Initialization is in progress
Logical drive initialization has
completed
Logical drive initialization has paused Resume the initialization when ready.
Logical drive initialization has resumed No action is required.
Logical drive initialization has stopped If this action was not intentional, check
the logical drive’s status.
Logical drive initialization marks the
logical drive offline
Replace the failed physical drive.
Delete and recreate the logical drive.
Logical drive initialization is aborted due
to an internal error.
Reduce system load on the VTrak.
Logical drive initialization is queued
No action is required.
Quick logical drive initialization has
started
Quick logical drive initialization has
completed
Quick logical drive initialization has
paused
Resume the initialization when ready.
Quick logical drive initialization has
resumed
No action is required.
Quick logical drive initialization has
stopped
If this action was not intentional, check
the logical drive’s status.
Quick logical drive initialization marks
the logical drive offline
Replace the failed physical drive.
Delete and recreate the logical drive.
Quick logical drive Initialization is
aborted due to an internal error
Reduce system load on the VTrak.
Reported Event Corrective Action
Vue de la page 356
1 2 ... 352 353 354 355 356 357 358 359 360 361 362 ... 435 436

Commentaires sur ces manuels