Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
12 of 34
Promise Array Management
If you are running Promise Array Management (PAM) software on your system, the
monitoring utility will send on-screen alerts and messages to call your attention to an
array in trouble. PAM works the same whether you have a SuperTrak SX6000 or an
UltraTrak system.
The disk drive on Channel 4 has been deactivated.
The array has gone CRITICAL.
Degraded and critical mean the same thing.
Rebuilding has begun. If Channel 4 is part of this array, you
know which disk drive you may have to remove and test.
Check the PAM user interface for more information.
This UltraTrak has four disk drives all of which belong to one array. The PAM user
interface verifies that the array is critical and that there is no disk drive reported for
Channel 4.