Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
11 of 34
Warnings
Do not substitute third-party disk utilities, because they lack the
proprietary functions of the drive manufacturer’s program.
If you remove a disk drive, reconnect it to its original Channel.
Shut down the UltraTrak and your computer before removing or
installing disk drives.
Results and Action
The results of the diagnostic test will tell you whether the disk drive can be returned to
service or it must be replaced.
If the disk drive is serviceable, reinstall it, boot your computer, and allow UltraTrak
to rebuild the array.
If the disk drive is not serviceable:
1. Obtain a replacement drive of the same capacity.
2. Install the new drive on the same channel where the failed drive was.
3. Boot your computer and UltraTrak, and allow UltraTrak to rebuild the array.