Promise Technology SuperTrack EX8658 Manuel d'utilisateur Page 273

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 324
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 272
Chapter 7: Technology Background
259
The physical drive in channel 2 fails. The disk array becomes degraded and its
logical drives go critical. The SuperTrak controller automatically rebuilds the disk
array using the spare drive, the physical drive in channel 4.
As we saw in the example of Automatic Transition, if you replace the failed
physical drive in channel 2, the SuperTrak controller would transition the data
from the physical drive in channel 4 to the new drive in channel 2.
But if you wanted to use a different physical drive in your array, such as the
unassigned drive in channel 3, you would run the Transition function manually.
When the Manual Transition is finished:
The physical drives in channels 1 and 3 belong to the disk array.
The physical drive channel 2 is still failed and unusable.
The physical drive in channel 4 is a revertible spare drive.
At this point, after running the Manual Transition, you would replace the failed
drive in channel 2. The replacement drive in channel 2 will remain unconfigured
until you assign it to a disk array or as a spare.
Vue de la page 272
1 2 ... 268 269 270 271 272 273 274 275 276 277 278 ... 323 324

Commentaires sur ces manuels

Pas de commentaire