Promise Technology FastTrak TX2200 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Réseaux de disques Promise Technology FastTrak TX2200. Promise Technology FastTrak TX2200 User manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 78
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
F
AST
T
RAK
TX2200 / TX4200
U
SER
M
ANUAL
Version 1.4
Vue de la page 0
1 2 3 4 5 6 ... 77 78

Résumé du contenu

Page 1 - TX2200 / TX4200

FASTTRAK TX2200 / TX4200USER MANUALVersion 1.4

Page 2 - Recommendations

Fast Trak TX2200 / TX4200 User Manual6

Page 3 - Contents

7Chapter 2: Installation• Unpack Your FastTrak Card (below)• Install the FastTrak Card (page 8)• Install the Disk Drives (page 9)• Create Your Logical

Page 4

Fast Trak TX2200 / TX4200 User Manual8Install the FastTrak Card The FastTrak TX2200 or TX4200 Serial ATA RAID card fits into any available PCI slot on

Page 5 - Chapter 1: Introduction

Chapter 2: Installation92. Remove the inside slot cover of an available 32-bit PCI slot on the motherboard.Install the FastTrak Serial ATA RAID card i

Page 6 - FastTrak TX Series

Fast Trak TX2200 / TX4200 User Manual103. Attach one Serial ATA data cable to each Serial ATA disk drive. Then attach the other ends of the cables to

Page 7 - Key Features and Benefits

Chapter 2: Installation11If you are using a Promise SuperSwap 1100 or 4100 enclosure in your PC:• Connect the power cables to the SuperSwap enclosure.

Page 8

Fast Trak TX2200 / TX4200 User Manual12This is the fastest and easiest method to creating your first logical disk. Performance Logical Disk (Array)Use

Page 9 - Specifications

Chapter 2: Installation134. If you chose to initialize, press Y to verify that you want your disks initialized.5. Press Esc twice to exit FastBuild a

Page 10

Fast Trak TX2200 / TX4200 User Manual14Proceed to Chapter 4 on page 39 and install the FastTrak driver. Security Logical Disk (Array) with an Existing

Page 11 - Chapter 2: Installation

Chapter 2: Installation15 3. Press Y for the Create and Duplicate option. The window below will appear asking you to select the Source drive to use.4.

Page 12 - Install the FastTrak Card

FastTrak TX2200 / TX4200 User ManualiiCopyright© 2004 Promise Technology, Inc. All Rights Reserved.Copyright by Promise Technology, Inc. (Promise Tech

Page 13 - Install the Disk Drives

Fast Trak TX2200 / TX4200 User Manual16FastBuild will copy all data from the Source drive to the Target drive and report its progress in percent compl

Page 14 - FastT rak

Chapter 2: Installation17The window below will appear.3. For the Create and Quick Initialize option:• Press I if you have a two-drive RAID 1 logical d

Page 15 - Create Your Logical Disk

Fast Trak TX2200 / TX4200 User Manual18

Page 16

19Chapter 3: FastBuild™ Configuration Utility• Viewing the FastTrak BIOS Screen, below• Navigate the FastBuild Setup Menu, page 20• Create Logical Dis

Page 17

Fast Trak TX2200 / TX4200 User Manual20Rebuilding – The process of reconstructing a logical disk in Critical mode by placing redundant data on a repla

Page 18

Chapter 3: FastBuild Configuration Utility21To create a new logical disk automatically, press 1 and see Create Logical Disks Automatically on page 21.

Page 19

Fast Trak TX2200 / TX4200 User Manual22PerformanceRAID 0 (Stripe) supports the high performance. The storage capacity equals the number of drives time

Page 20 - 50% Completed

Chapter 3: FastBuild Configuration Utility23 Change Between Spare and JBODBy default, unassigned disk drives are designated as Spares. You can designa

Page 21

Fast Trak TX2200 / TX4200 User Manual244. Press Ctrl-Y to confirm.The disk is re-designated as JBOD. Spare disks are not recognized by your PC until

Page 22

Chapter 3: FastBuild Configuration Utility25Create Logical Disks Manually• Logical Disk Specifications (below)• Create a RAID 0 Logical Disk (page 27)

Page 23

iiiContentsChapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1About This Manual . . . .

Page 24 - Using the Main Menu

Fast Trak TX2200 / TX4200 User Manual26Gigabyte Rounding feature permits the installation of a replacement drive that is slightly smaller (within 1 gi

Page 25

Chapter 3: FastBuild Configuration Utility27Create a RAID 0 Logical Disk1. From the FastBuild Main Menu, press 3 to choose Define Array.The Define Arr

Page 26 - View/Change Drive Assignments

Fast Trak TX2200 / TX4200 User Manual283. Under the Define Array Menu section, press the arrow keys to highlight the RAID Mode.4. Press the Spacebar t

Page 27 - Change Between Spare and JBOD

Chapter 3: FastBuild Configuration Utility29Create a RAID 1 Logical Disk 1. From the FastBuild Main Menu, press 3 to choose Define Array.The Define Ar

Page 28

Fast Trak TX2200 / TX4200 User Manual303. Under the Define Array Menu section, press the arrow keys to highlight the RAID Mode.4. Press the Spacebar t

Page 29 - Create Logical Disks Manually

Chapter 3: FastBuild Configuration Utility311. From the FastBuild Main Menu, press 3 to choose Define Array.2. Press the arrow keys to highlight the l

Page 30 - Number of Disk Drives

Fast Trak TX2200 / TX4200 User Manual3210. Press the arrow keys to choose which drive contains the existing data to be copied. 11. Press Ctrl-Y to Sav

Page 31 - Create a RAID 0 Logical Disk

Chapter 3: FastBuild Configuration Utility3313. Press Esc twice to exit FastBuild and continue booting your computer.Hot Spare DriveThis arrangement a

Page 32 - N - Create Only

Fast Trak TX2200 / TX4200 User Manual34Delete a Logical Disk 1. From the FastBuild Main Menu, press 4 to select Delete Array.2. In the Delete Arra

Page 33 - Create a RAID 1 Logical Disk

Chapter 3: FastBuild Configuration Utility35 5. Press Ctrl-Y to confirm that you want to delete the logical disk.The option appears to remove the Boot

Page 34

Fast Trak TX2200 / TX4200 User ManualivWindows 2000New Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35

Fast Trak TX2200 / TX4200 User Manual36Rebuild a Mirrored Logical DiskWhen a mirrored (RAID 1 or 10) logical disk suffers a disk drive failure, it goe

Page 36

Chapter 3: FastBuild Configuration Utility37.Follow these steps to use the Rebuild Array feature:1. Press Ctrl-F to enter FastBuild Main Menu.2. Selec

Page 37 - Hot Spare Drive

Fast Trak TX2200 / TX4200 User Manual38 The Rebuild Array - Assign Spare Drive menu appears (below).9. Press the arrow keys to highlight the replaceme

Page 38 - Delete a Logical Disk

39Chapter 4: Install DriversFollowing are driver installation procedures for the Windows operating systems that support the FastTrak TX2200 and TX4200

Page 39 - Any Key - Back / Ctrl-Y - Yes

Fast Trak TX2200 / TX4200 User Manual40Windows Server 2003 New InstallationThe following details the installation of the FastTrak Serial ATA RAID Cont

Page 40

Chapter 4: Install Drivers41Existing InstallationAfter installing the FastTrak Serial ATA RAID Controller card and rebooting your system, Windows Serv

Page 41

Fast Trak TX2200 / TX4200 User Manual42Windows XPNew InstallationThe following details the installation of the FastTrak Serial ATA RAID Controller dri

Page 42

Chapter 4: Install Drivers43Existing InstallationAfter installing the FastTrak Serial ATA RAID Controller card and rebooting your system, Windows XP s

Page 43 - Chapter 4: Install Drivers

Fast Trak TX2200 / TX4200 User Manual44Windows 2000New InstallationThe following details the installation of the FastTrak Serial ATA RAID Controller

Page 44 - Windows Server 2003

Chapter 4: Install Drivers45Existing InstallationAfter installing the FastTrak Serial ATA RAID Controller card and rebooting your system, Windows 2000

Page 45 - Confirm Installation

1Chapter 1: Introduction• About This Manual, below• Overview, page 2• FastTrak TX Series, page 2• Promise Array Management (PAM), page 3• Key Features

Page 46 - Windows XP

Fast Trak TX2200 / TX4200 User Manual46

Page 47

47Chapter 5: RAID Concepts• FastTrak Serial ATA RAID Controller Card, below• Logical Disk Terms, page 48• RAID Levels, page 51FastTrak Serial ATA RAID

Page 48 - Windows 2000

Fast Trak TX2200 / TX4200 User Manual48Logical Disk TermsLogical diskA logical disk (array) is formed from a group of two or more disk drives that app

Page 49

Chapter 5: RAID Concepts49Stripe Block SizeThe size selected (32, 64, 128 KB) affects how FastTrak sends data blocks to and receives them from the dri

Page 50

Fast Trak TX2200 / TX4200 User Manual50How FastTrak Orders Logical DisksDuring startup, the logical disks on the FastTrak Serial ATA Controller card a

Page 51 - Chapter 5: RAID Concepts

Chapter 5: RAID Concepts51RAID LevelsStripe (RAID 0)Reads and writes sectors of data interleaved between multiple drives. When any disk member fails,

Page 52 - Logical Disk Terms

Fast Trak TX2200 / TX4200 User Manual52Mirror (RAID 1)Writes duplicate data on to a pair of drives while reads are performed in parallel. RAID 1 is fa

Page 53 - Gigabyte Rounding

Chapter 5: RAID Concepts53Mirror / Stripe (RAID 10)A combination of RAID 0 and RAID 1 logical disks. It can increase performance by reading and writin

Page 54

Fast Trak TX2200 / TX4200 User Manual54Dual Data RedundancyOne unique (though rarely used) feature of RAID 10 is dual fault tolerance. In some cases,

Page 55 - RAID Levels

55Chapter 6: Troubleshooting & Tips• Motherboard Issues, below• System CMOS Issues, page 56• Drive-Related Issues, page 57• Operating System-Relat

Page 56 - Mirror (RAID 1)

Fast Trak TX2200 / TX4200 User Manual2OverviewThe PC which you are using either already contains FastTrak TX2200 or TX4200 RAID Controller card instal

Page 57 - Mirror / Stripe (RAID 10)

Fast Trak TX2200 / TX4200 User Manual56Intermittent data problemsOverclocking the PCI bus may cause the system to hang or data corruption. If you expe

Page 58 - Dual Data Redundancy

Chapter 6: Troubleshooting & Tips57Drive-Related IssuesCritical logical disk (array) status error reported during bootIf a critical status error m

Page 59 - Motherboard Issues

Fast Trak TX2200 / TX4200 User Manual58Unable to partition or format logical diskThis condition may occur when the Reserve Sector of one of the drives

Page 60 - System CMOS Issues

Chapter 6: Troubleshooting & Tips59Operating System-Related IssuesThe Operating System no longer boots after creating a Mirrored Logical Disk usin

Page 61 - Drive-Related Issues

Fast Trak TX2200 / TX4200 User Manual60Performance TipsHere are some tips that may optimize performance in a RAID 0 striped logical disk. If you are u

Page 62

61Chapter 7: Support• Frequently Asked Questions, below• Contact Technical Support, page 65• Limited Warranty, page 67• Return Product for Repair, pag

Page 63

Fast Trak TX2200 / TX4200 User Manual62• Reset the configuration data in your CMOS. This is usually an option in the PnP section of your CMOS. • Othe

Page 64 - Performance Tips

Chapter 7: Support63Do the disk drives on the FastTrak Controller have to be the same size?The disk drives connected to the FastTrak Serial ATA RAID C

Page 65 - Chapter 7: Support

Fast Trak TX2200 / TX4200 User Manual64How do I partition/format my FastTrak logical disk?The FastTrak Serial ATA RAID Controller represents the logic

Page 66 - Drive Issues

Chapter 7: Support65Contact Technical SupportPromise Technical Support provides several support options for Promise users to access information and up

Page 67

Chapter 1: Introduction3Should a drive that is part of a mirrored logical disk fail, FastTrak TX2200 and TX4200 use the mirrored drive (which contains

Page 68 - Post-Installation

Fast Trak TX2200 / TX4200 User Manual66Europe, Africa and Middle EastPacific RimChinaE-mail Support [email protected] Technical Support +31 (0) 40

Page 69 - Contact Technical Support

Chapter 7: Support67Limited WarrantyPromise Technology, Inc. (“Promise”) warrants that for three (3) years from the time of the delivery of the produc

Page 70 - Pacific Rim

Fast Trak TX2200 / TX4200 User Manual68No other document, statement or representation may be relied on to vary the terms of this limited warranty.Prom

Page 71 - Limited Warranty

Chapter 7: Support69The technician will assist you in determining whether the product requires repair. If the product needs repair, the Technical Supp

Page 72 - Return Product For Repair

Fast Trak TX2200 / TX4200 User Manual70

Page 73

71Appendix A: Partition and FormatIn order for your operating system to recognize and work with the disk drives attached to your FastTrak TX2200 or TX

Page 74

FastTrak TX2200 / TX4200 User Manual723. Click the Next button to start the Wizard.4. In the following windows, select Disk 1 to Initialize. Do not se

Page 75

Appendix A: Partition and Format736. Click the Next button to start the wizard.7. In the following windows, do the following actions. Click Next to mo

Page 76

FastTrak TX2200 / TX4200 User Manual74When formatting is complete, your logical disk will appear as a hard drive in the Disk Management window (above)

Page 77

Fast Trak TX2200 / TX4200 User Manual4PCI Plug-n-Play, PCI Interrupt sharing and coexists with motherboard IDE and SCSI controllersEasy to install; su

Page 78 - (below)

Chapter 1: Introduction5Specifications• Low-profile printed circuit board• PCI Slot 33MHz or 66MHz• Controller card dimensionsTX2200 (HWD): 2.25 x 4.6

Commentaires sur ces manuels

Pas de commentaire