Promise Technology Network Device EX8650 Manuel d'utilisateur Page 259

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 318
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 258
Chapter 7: Technology Background
245
RAID 50
A RAID 50 Source logical drive can migrate to the following Target logical drives:
RAID 60
A RAID 60 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 5 16 physical drives maximum.
RAID 50 must have less than 16 physical drives.
RAID 6 16 physical drives maximum.
RAID 50 must have less than 16 physical drives.
RAID 10 Even number of physical drives.
RAID 50 Add physical drives. 16 per axle maximum.
RAID 60 8 physical drives minimum, 16 per axle maximum.
Target Requirements
RAID 6 16 physical drives maximum.
RAID 60 must have less than 16 physical drives.
RAID 60 Add physical drives. 16 per axle maximum.
Vue de la page 258
1 2 ... 254 255 256 257 258 259 260 261 262 263 264 ... 317 318

Commentaires sur ces manuels

Pas de commentaire